@@ -83,28 +83,31 @@ $adeiChannel = array(
 			   "aircoils__aircoils_rep__0__92",  //PS2 Status
 			   "aircoils__aircoils_rep__0__93"   //PS2 Status
 			   ),
-			 array(
-			   "fpd__katrin_rep__0__153",
-			   "fpd__katrin_rep__0__158"
+			 array(  // detector magnets status (index #4)
+			   "fpd0__FPD__520_IST_MAIN__153", // Current through pinch-magnet coil [521-ELV-0-1205-0001]
+			   "fpd0__FPD__520_IST_MAIN__158"  // Current through detector-magnet coil [521-ELV-0-2205-0001]
 			   ),
 		     // Baffle vacuum  (index 5, former egun part)
 		     array(
 			   "csms__ControlSystem_MS__432VAK_Kryoleitung__9"
 			   ),
-		     array(
-			   "fpd__katrin_rep__0__43",
-			   "fpd__katrin_rep__0__66",
-			   "fpd__katrin_rep__0__80",
-			   "fpd__katrin_rep__0__99",
-			   "fpd__katrin_rep__0__112",
-			   "fpd__katrin_rep__0__113",
-			   "fpd__katrin_rep__0__116",
-			   "fpd__katrin_rep__0__117",
-			   "fpd__katrin_rep__0__118",
-			   "fpd__katrin_rep__0__60",
-			   "fpd__katrin_rep__0__62",
-			   "fpd__katrin_rep__0__114",
-			   "fpd__katrin_rep__0__51"
+		     array(  // detector hardware and electronics status + ORCA (index #6)
+			   "fpd0__FPD__520_IST_MAIN__43", // Heater Output is ON for PID Loop 2 [852-HEE-0-1002-0591]
+			   "fpd0__FPD__520_IST_MAIN__66", // XHV chamber pressure (CC) [522-RPP-3-1250-0001]
+			   "fpd0__FPD__520_IST_MAIN__80", // PAE voltage readback [525-EHV-0-1050-0001]
+			   "fpd0__FPD__520_IST_MAIN__99", // XHV cryopump temperature [522-PCR-3-1100-0001]
+			   "fpd0__FPD__520_IST_MAIN__112", // 12-V-supply (FET) voltage readback [527-ELV-0-1601-0001]
+			   "fpd0__FPD__520_IST_MAIN__113", // 8-V-supply voltage readback [527-ELV-0-1601-0002]
+			   "fpd0__FPD__520_IST_MAIN__116", // positiv 6V supply (preamp) voltage readback [527-ELV-0-1603-0001]
+			   "fpd0__FPD__520_IST_MAIN__117", // negative 6V supply (preamp) voltage readback [527-ELV-0-1603-0002]
+			   "fpd0__FPD__520_IST_MAIN__118", // 120-V-supply (bias) voltage readback [527-ELV-0-1604-0001]
+			   "fpd0__FPD__520_IST_MAIN__60",  // Gamma source is all the way out [524-AAI-0-1100-0002]
+			   "fpd0__FPD__520_IST_MAIN__62",  // Electron source is all the way iout [524-AAI-0-2100-0002]
+			   "fpd0__FPD__520_IST_MAIN__114", // Carousel Temperature [527-RTP-6-1285-0001]
+			   "fpd0__FPD__520_IST_MAIN__51",   // XHV cryopump gate valve status [852-VAO-3-1011-0300]	
+   			   "fpd0__FPD__520_IST_MAIN__129",  // ORCA run-subrun number [530-CHN-0-0001-0001]
+			   "fpd0__FPD__520_IST_MAIN__0",    // Timestamp 1 (for SC system) [535-TTT-0-0000-0001]
+			   "fpd0__FPD__520_IST_MAIN__1"     // Timestamp 2 (for SC system) [535-TTT-0-0000-0002]
 			   ),
 		     array(
 			   "csms__ControlSystem_MS__432VAK_PumpPort2__33",
@@ -337,11 +340,11 @@ $adeiChannel = array(
 			   "precmm0__PrecMagnet__SouthRing__16"
 			   ),
 		     // FPD status values (index 19)
-		     array(
-			   "fpd__katrin_rep__0__198",
-			   "fpd__katrin_rep__0__199",
-			   "fpd__katrin_rep__0__200",
-			   "fpd__katrin_rep__0__180"   // saphire window at port 0100 temperature
+		     array(  // detector platform and environment status
+			   "fpd0__FPD__520_IST_MAIN__198",  // Atmospheric pressure on detector platform [535-RPY-0-1005-0001]
+			   "fpd0__FPD__520_IST_MAIN__199",  // Temperature on detector platform [535-RTY-0-1010-0001]
+			   "fpd0__FPD__520_IST_MAIN__200",  // Relative humidity on detector platform [535-RMY-0-1015-0001]
+			   "fpd0__FPD__520_IST_MAIN__180"  // Light hammer sapphire window temperature [526-HEX-0-3210-0001]
 			   ),
 		     array(
 			   "csms__ControlSystem_MS__435HZ_Temperatur__27",