@@ -92,23 +92,24 @@ $adeiChannel = array(
|
|
|
"csms__ControlSystem_MS__432VAK_Kryoleitung__9"
|
|
|
),
|
|
|
array( // detector hardware and electronics status + ORCA (index #6)
|
|
|
- "fpd0__FPD__520_IST_MAIN__43", // Heater Output is ON for PID Loop 2 [852-HEE-0-1002-0591]
|
|
|
- "fpd0__FPD__520_IST_MAIN__66", // XHV chamber pressure (CC) [522-RPP-3-1250-0001]
|
|
|
- "fpd0__FPD__520_IST_MAIN__80", // PAE voltage readback [525-EHV-0-1050-0001]
|
|
|
- "fpd0__FPD__520_IST_MAIN__99", // XHV cryopump temperature [522-PCR-3-1100-0001]
|
|
|
- "fpd0__FPD__520_IST_MAIN__112", // 12-V-supply (FET) voltage readback [527-ELV-0-1601-0001]
|
|
|
- "fpd0__FPD__520_IST_MAIN__113", // 8-V-supply voltage readback [527-ELV-0-1601-0002]
|
|
|
- "fpd0__FPD__520_IST_MAIN__116", // positiv 6V supply (preamp) voltage readback [527-ELV-0-1603-0001]
|
|
|
- "fpd0__FPD__520_IST_MAIN__117", // negative 6V supply (preamp) voltage readback [527-ELV-0-1603-0002]
|
|
|
- "fpd0__FPD__520_IST_MAIN__118", // 120-V-supply (bias) voltage readback [527-ELV-0-1604-0001]
|
|
|
- "fpd0__FPD__520_IST_MAIN__60", // Gamma source is all the way out [524-AAI-0-1100-0002]
|
|
|
- "fpd0__FPD__520_IST_MAIN__62", // Electron source is all the way iout [524-AAI-0-2100-0002]
|
|
|
- "fpd0__FPD__520_IST_MAIN__114", // Carousel Temperature [527-RTP-6-1285-0001]
|
|
|
- "fpd0__FPD__520_IST_MAIN__51", // XHV cryopump gate valve status [852-VAO-3-1011-0300]
|
|
|
- "fpd0__FPD__520_IST_MAIN__129", // ORCA run-subrun number [530-CHN-0-0001-0001]
|
|
|
- "fpd0__FPD__520_IST_MAIN__0", // Timestamp 1 (for SC system) [535-TTT-0-0000-0001]
|
|
|
- "fpd0__FPD__520_IST_MAIN__1" // Timestamp 2 (for SC system) [535-TTT-0-0000-0002]
|
|
|
- ),
|
|
|
+ "fpd0__FPD__520_IST_MAIN__43", // Heater Output is ON for PID Loop 2 [852-HEE-0-1002-$
|
|
|
+ "fpd0__FPD__520_IST_MAIN__66", // XHV chamber pressure (CC) [522-RPP-3-1250-0001]
|
|
|
+ "fpd0__FPD__520_IST_MAIN__80", // PAE voltage readback [525-EHV-0-1050-0001]
|
|
|
+ "fpd0__FPD__520_IST_MAIN__98", // XHV cryopump temperature [522-PCR-3-1100-0001]
|
|
|
+ "fpd0__FPD__520_IST_MAIN__111", // 12-V-supply (FET) voltage readback [527-ELV-0-1601$
|
|
|
+ "fpd0__FPD__520_IST_MAIN__112", // 8-V-supply voltage readback [527-ELV-0-1601-0002]
|
|
|
+ "fpd0__FPD__520_IST_MAIN__114", // positiv 6V supply (preamp) voltage readback [527-E$
|
|
|
+ "fpd0__FPD__520_IST_MAIN__115", // negative 6V supply (preamp) voltage readback [527-$
|
|
|
+ "fpd0__FPD__520_IST_FAST__5", // 120-V-supply (bias) voltage readback [527-ELV-0-1604$
|
|
|
+ "fpd0__FPD__520_IST_MAIN__60", // Gamma source is all the way out [524-AAI-0-1100-00$
|
|
|
+ "fpd0__FPD__520_IST_MAIN__62", // Electron source is all the way iout [524-AAI-0-210$
|
|
|
+ "fpd0__FPD__520_IST_MAIN__113", // Carousel Temperature [527-RTP-6-1285-0001]
|
|
|
+ "fpd0__FPD__520_IST_MAIN__51", // XHV cryopump gate valve status [852-VAO-3-1011-03$
|
|
|
+ "fpd0__FPD__520_IST_MAIN__124", // ORCA run-subrun number [530-CHN-0-0001-0001]
|
|
|
+ "fpd0__FPD__520_IST_MAIN__0", // Timestamp 1 (for SC system) [535-TTT-0-0000-0001]
|
|
|
+ "fpd0__FPD__520_IST_MAIN__1" // Timestamp 2 (for SC system) [535-TTT-0-0000-0002]
|
|
|
+ ),
|
|
|
+
|
|
|
array(
|
|
|
"csms__ControlSystem_MS__432VAK_PumpPort2__33",
|
|
|
"csms__ControlSystem_MS__432VAK_PumpPort2__6",
|
|
@@ -475,14 +476,17 @@ $adeiChannel = array(
|
|
|
array(
|
|
|
"hv0__DLL_Katrin_HV__436HV_IST_FAST__2", //K35 divider voltage reading
|
|
|
"hv0__DLL_Katrin_HV__436HV_IST_FAST__3", //K35 divider voltage timestamp
|
|
|
- "hv0__DLL_Katrin_HV__436HV_IST_FAST__4", //K35 divider voltage measurement running
|
|
|
+ "hv0__DLL_Katrin_HV__436HV_IST_FAST__4", //K35 divider voltage measurement running flag
|
|
|
"hv0__DLL_Katrin_HV__436HV_IST_FAST__5", //K65 divider voltage reading
|
|
|
"hv0__DLL_Katrin_HV__436HV_IST_FAST__6", //K65 divider voltage timestamp
|
|
|
- "hv0__DLL_Katrin_HV__436HV_IST_FAST__7", //K65 divider voltage measurement running
|
|
|
- "hv0__DLL_Katrin_HV__436HV_IST_FAST__8", //IE Common DVM voltage voltage reading KAL1
|
|
|
- "hv0__DLL_Katrin_HV__436HV_IST_FAST__9", //IE Common DVM voltage voltage timestamp KAL1
|
|
|
- "hv0__DLL_Katrin_HV__436HV_IST_FAST__10", //IE Common DVM voltage voltage measurement running
|
|
|
- ),
|
|
|
+ "hv0__DLL_Katrin_HV__436HV_IST_FAST__7", //K65 divider voltage measurement running flag
|
|
|
+ "hv0__DLL_Katrin_HV__436HV_IST_FAST__8", //IE Common DVM voltage reading KAL1
|
|
|
+ "hv0__DLL_Katrin_HV__436HV_IST_FAST__9", //IE Common DVM timestamp KAL1
|
|
|
+ "hv0__DLL_Katrin_HV__436HV_IST_FAST__10", //IE Common DVM measurement running flag
|
|
|
+ "hv0__DLL_Katrin_HV__436HV_IST_FAST__11", //JLR divider@PS DVM voltage reading KAL2
|
|
|
+ "hv0__DLL_Katrin_HV__436HV_IST_FAST__12", //JLR divider@PS DVM timestamp KAL2
|
|
|
+ "hv0__DLL_Katrin_HV__436HV_IST_FAST__13", //JLR divider@PS DVM measurement running flag
|
|
|
+ ),
|
|
|
|
|
|
// Detector Valve and HV grounding interlock (index 31)
|
|
|
array(
|
|
@@ -644,7 +648,13 @@ $adeiChannel = array(
|
|
|
array(
|
|
|
"egunrs__EgunRS__0__150" //111-REU-0-2402 egun laser beam monitor readout (> 2 on, <= 2 off)
|
|
|
)
|
|
|
+ ),
|
|
|
+ // PS Ground Switch (index 48)
|
|
|
+ array(
|
|
|
+ "csps__ControlSystem_PS__416HV_Interlook__27" //416-HVS-0-1101-BED_Val PS-HV-Ground-Switch
|
|
|
+ )
|
|
|
);
|
|
|
|
|
|
+
|
|
|
?>
|
|
|
|