Browse Source

included ion monitor status

Thomas Thümmler 3 years ago
parent
commit
fb93b9c039
1 changed files with 23 additions and 3 deletions
  1. 23 3
      SDS_status_main.php

+ 23 - 3
SDS_status_main.php

@@ -53,7 +53,8 @@ if (substr($ip, 0, 13) == "141.52.12.52")
 	$value = $adeiValue[36][1];
 	$clearance = $adeiValue[36][0];
 	$pic = "valve";
-	if (($value == 1) && ($clearance == 1)) $pic = $pic . "On";
+    $V4_open = false;
+	if (($value == 1) && ($clearance == 1)) {$pic = $pic . "On"; $V4_open = true;}
 	else if (($value == 0) && ($clearance == 0)) $pic = $pic . "Off";
 	else if (($value == 0) && ($clearance == 1)) $pic = $pic . "FREE";
 	else if (($value == 1) && ($clearance == 0)) $pic = $pic . "Error";
@@ -1312,11 +1313,30 @@ placeBox(140, 230, $mace_setting["Config"] , 85, 3, $color);
 
 
 
+// ########## PS Ion Monitor status display ##########
+if ($adeiValue[39][1] < 0.5)
+  {
+    $ion_mon_stat = "active";
+    $color = "#4CFF00";
+  }
+else
+  {
+    $ion_mon_stat = "bypassed";
+    $color = "#FF0000";
+    placePicWithLink(130, 33, "alarm_flash.gif", 50, "Ion alarm not armed!", $adeiChannel[39][1]);
+  }
+
+if ($V4_open) {
+  placeText(115+65, 4, "Ion Mon", 105, 5, "#000000");
+  placeBox(140+65, 2, $ion_mon_stat , 105, 3, $color);
+}
+
+	
 	// ########## HIGH VOLTAGE SWITCH ##########
-        $value = $adeiValue[31][1];
+  	$value = $adeiValue[31][1];
 	$pic = "switch";
 	if ($value == 1) $pic = $pic . "Open";
-	else if ($value == 0) $pic = $pic . "Closed";
+	else if ($value	== 0) $pic = $pic . "Closed";
 	placePicWithLink(474, 440, $pic . ".png", 80, "status high-voltage grounding switch", $adeiChannel[31][1]);
 
 ?>